Glossary entry

English term or phrase:

stress-shielding

Norwegian translation:

avlastning

Added to glossary by anebjordal
Jul 22, 2009 19:51
14 yrs ago
3 viewers *
English term

stress-shielding

English to Norwegian Medical Medical: Instruments
Kontekst: Decrease in density of bone and/or necrosis of bone due to stress shielding.

Discussion

Koen Speetjens (X) Jul 27, 2009:
Alle kan ta feil... Enig med Tore og Egil. Slik jeg forstår referansen din, Svein, er løsningen av protesen en følge av benresorpsjon, som igjen er en følge av at benet ikke får den stimulansen lenger til å holde seg sterk på grunn av "stress-shielding" (avlastning eller skjerming). Jeg er ganske sikker at du tar feil her :) Avstøting er rejection.
Egil Presttun Jul 27, 2009:
Det dreier seg ikke om utstøting av fremmedlegemer Stress-shielding betyr at det blir mindre vekt (belastning) på ett eller flere bein. Det fører til svekkelse. Fenomenet er det samme som astronauter opplever i vektløshet; bein blir svakere pga. mindre belastning.
http://en.wikipedia.org/wiki/Stress_shielding
anebjordal (asker) Jul 27, 2009:
stress-shielding Hmmm. Jeg gjorde noen søk på nettet, og finner motstridende informasjon. Skal se på det når jeg har litt bedre tid...
Svein Hartwig Djaerff Jul 27, 2009:
Avlastning Dette er feil. Jeg har forklart hva det er med henvisninger og avlastning er noe HELT annet! Men slik er det jo ofte i dette forumet :)

Proposed translations

1 day 17 hrs
Selected

avlastning

Det er mange eksempler på bruk av entlastnung på tysk i forbindelse med stress shielding

--------------------------------------------------
Note added at 4 days (2009-07-27 17:53:31 GMT) Post-grading
--------------------------------------------------

I suspect this is the source text used for a bone fixation device:
POSSIBLE ADVERSE EFFECTS
1. Decrease in density of bone and/or necrosis of bone due to stress shielding.

The stress shielding is the actual redistribution of load (and consequently stress on the bone) that, as an example, occurs when the femoral head is replaced by the femoral component of a total hip replacement.
The "new" stress may result in decrease in bone density.
http://www.bananarepublican.info/Stress_shielding.htm
explains:
The wight bearing situation changes when there is a total hip joint device. The much stiffer shaft component of the total hip takes over the majority of the load stresses.

Now the stresses of the body weight flow through the total joint center and then through the shaft component of the device. The flow of the stresses then enters the thighbone at the tip of the femoral component. The consequences of the changed flow of stresses are two:

First, the upper part of the thighbone is unloaded; it contains less bone tissue and it is weaker, more susceptible to fracture. In the right hand picture the stress shielded area is whiter.

Second, the skeleton around the tip of the femoral component is overloaded; it becomes more thick and stronger. In the right hand picture this area is darker. Unfortunately, the thickening of the skeleton is often painful. The patients with cementless shafts of total hip devices often claim about the pain in the thigh, especially during the first years after the surgery.

Does that satisfy you, Svein Hartwig?
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Alle høres bra ut, men jeg valgte denne. Takker for det, Tore."
10 hrs

avstøting

Eventuelt kan du beholde det engelske uttrykket og sette avstøting i parentes. Avstøting er noe som skjer både med implantater, proteser og ved organtransplantasjoner og er en kroppsfunksjon for å bli kvitt fremmedlegemer. Ved transp. i benstrukturer beskytter benvevet seg ved å degenerere og trekke seg tilbake fra proteseinnfestingen.

http://www.biomedical-engineering-online.com/content/8/1/7
Something went wrong...
+1
58 mins

belastningsskjerming

.

--------------------------------------------------
Note added at 3 days14 hrs (2009-07-26 09:52:07 GMT)
--------------------------------------------------

"Redusert bentetthet som følge av belastningsskjerming."
http://www.lorenzsurgical.com/downloads/01-50-1114 Rev C .pd...
Peer comment(s):

agree Hilde Granlund
3 days 18 hrs
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search